FAR 25.853 Aircraft Material Combustion Performance Test - Vertical Burning Test

ZONSKY can produce Vertical Burning Tester. Get a quote.

Material Flame Retardant Test, Fire Test Far25.853 - Standard Name

  • Far25.853: Fire Protection for compartment interior

  • Far25.853: Fire Protection of Aircraft Interior Materials - Flame Retardant and Fire Test

 
material combustion performance test FAR25.853 - vertical combustion test
             FAR25.853 Vertical Burning Test-Introduction

The device used is similar to UL94V and is used to determine the self-extinguishing properties of materials. According to the provisions of U.S. Federal Test Method Standard 191,5903.2, the test was conducted in a small room without artificial ventilation.

FAR25.853 vertical combustion test - test method

The width of the test specimen is 76mm. The specimen position is vertical. Combustion test with ignition source at the same level. The flame application time is 60s or 12s.
Test the following items:
- Burning length
- Open burning time
- Droplet time
 

material flame retardant testing, fire testing – other relevant standards

  • standard: ABD 0031 - airbus fire testing – flame, smoke and toxicity

  • standard smoke test: BSS7238 fire testing to smoke density

  • standard toxicity test: BSS7239 fire testing to toxicity

  • standard smoke density: ASTM E 662 fire testing to Smoke Density

 

Far 25.853 Test Method – Combustion Performance Test 

  • Vertical burning test is conducted in accordance with 14 FAR 25.853 b(4)), (App. F to part 25 part I § (a), 12-second vertical burning test and 60-second vertical burning test

  • density test performed in accordance with 14 FAR 25.853 (d), (App. F to part 25, part V)  

  • Combustion heat release test is conducted in accordance with 14 FAR 25.853 (d), Appendix F, Part IV  

  • seat in accordance with 14 FAR 25.853 (c, App.F to part II)  

  • Horizontal combustion test performed in accordance with 14 FAR 25.853 b(2,3), (App. F to part 25 part I § (a),(1)  

  • Cargo rack fire test conducted in accordance with 14 FAR 25.855 (App. F to part III) è  45° combustion test conducted in accordance with 14 FAR 25.853 (b), (App. F to part 25, part I § (6))  