Product Range | Level I | Level II |
Covering fabric | 1. No open flame for sample testing 2. The vertical burnt length of the sample shall not exceed 45mm. | The test did not reach level I |
interior fabric | 1. No open flame for sample testing 2. The vertical burnt length of the sample shall not exceed 38mm. | The test did not reach level I |
seam allowance | 1. No open flame for sample testing 2. The vertical burnt length of the sample shall not exceed 38mm. | The test did not reach level I |
filler | 1. No open flame for sample testing 2. The vertical burnt length of the sample shall not exceed 38mm. | The test did not reach level I |
decorative materials | 1. No open flame for sample testing 2. The vertical burnt length of the sample shall not exceed 38mm. | The test did not reach level I |
Sandwich material | 1. No open flame for sample testing 2. The vertical burnt length of the sample does not exceed 51mm | The test did not reach level I |