German Standard: DIN 4102-1 -- Fire performance requirements and test classification levels of building materials
ZONSKY can produce Fire performance tester of building materials Compliance: DIN 4102-1 . Get a quote.
The following content will elaborate on the German standard DIN 4102-1, the classification grade standard for building material requirements and testing in the fire resistance of building materials and components:
DIN 4102-1 Fire performance requirements and test classification levels of building materials - Standard name:
DIN 4102-1 Fire behaviour of building materials and elements Part 1: Classification of building materials Requirements and testing
DIN 4102-1: Fire performance of building materials and components Part 1: Classification levels of building materials requirements and tests
DIN 4102-1 Fire performance requirements and test classification levels of building materials - Overview of the standard:
DIN 4102-1 Fire performance requirements and test classification levels of building materials - Scope of application of materials:
Some of the applicable building materials are as follows:
-Board /Sheet -Composite materials -Assembly materials -Surface covering material -Insulation and insulation materials -coating -etc | -Decoration materials -Door curtains/curtains -Ceiling hanging material -Flame retardant -Foaming fire retardant coating -Pipes and fittings |
DIN 4102-1 Fire performance requirements and test classification levels of building materials - Standard analysis :
When the fire behavior of a material meets the characteristics determined by this standard, it is classified as:
A1 non-combustible materials | -Meets A2 requirements -Conduct total combustion calorific value test according to standards -Combustion smoke production test |
A2 non-combustible materials | -Tested according to DIN 4102-16 -Conduct non-flammability test or total combustion calorific value test according to standards -Combustion smoke production test |
B1 Flame retardant materials | -Tested to meet B2 requirements -The remaining sample length is greater than 15cm -The temperature does not exceed 200 degrees |
B2 Combustible materials | -The flame extends to the marking line after 20 seconds -The paper does not burn -Drip burning within 2s |
B3 Flammable materials | -Failed to meet B2 level |
DIN 4102-1 Fire performance requirements and test classification levels of building materials - related reference standards
DIN 4102-2: Fire performance of building materials and components – Building components – Definitions, requirements and tests
DIN 4102-4: Fire performance of building materials and components - Observation and design of classification of building materials, components
DIN 4102-8: Fire performance of building materials and components - small experimental furnace
DIN 4102-14: Fire behavior of building materials and components - Determination of combustion characteristics of floor covering systems using radiators (floor materials)
DIN 4102-15: Fire performance of building materials and components - Fire protection shafts
DIN 4102-16: Fire performance of building materials and components - Fire shaft test
DIN 18180: Plasterboards – Types, requirements and tests
DIN 50014: Climatic and technical applications – Standard atmosphere
DIN 50050-1: Material combustion performance test-small combustion box
DIN 50051: Material combustion performance test-burner
DIN 50055: Optical measurement system for smoke dispersibility testing
DIN 51622: Liquefied petroleum gas. Propane, propylene, butane, butene and their mixtures. Requirements
DIN 51900-2: Inspection of solid and liquid fuels. Determination of total calorific value and calculation of net calorific value using bomb calorimeter.
DIN 53436-1: Fire effluent toxicity test – Combustion equipment and test temperature determination
DIN 53436-2: Firefighting wastewater toxicity test - Thermal decomposition method
DIN 53436-3: Fire effluent toxicity test - Toxicity inhalation test method
DIN 53438-1: Examination of combustible materials. Reaction to ignition with a small flame - General data
DIN 66081: Classification of flammability of textiles – floor coverings
IS0 1716: 1973: Construction materials – Determination of latent heat
IS0 4783-2: 1989: Wire screens and woven wire cloths. Guide to pore size and wire diameter selection. Part 2: Recommended mesh and wire diameter combinations
Ä DIN 4102-1 Fire performance requirements and test classification levels of building materials – relevant similar standards
ü EN ISO 11925-2 Combustion reaction test - Flammability of construction products exposed to flame - Single flame test
ü EN 13501-1: Fire classification of building products and components - Part 1: Classification using test data on reaction to fire
ü NF P 92 - 501: French Flame Retardant Fire Test - Rigid Materials - M Level Burning Test
ü NF P 92 - 503: French Flame Retardant Fire Test – Flexible Materials – Class M Burning Test
ü BS 476: Flame retardant and fire protection test of British building materials