When the building partition is subjected to the fire resistance test according to the fire resistance test method specified in ISO 834-1, the water spray impact test shall be additionally carried out as required.
This Impact Testing Machine Comply with DIN 14521-1987、NF S61-820-1/IN12010、NF S61-820-2/IN12010 standards, It applies to the requirements of impact test for fire extinguishers of different capacities.
This Bending Test Machine is suitable for lining fire hose and fire hose bendability test and fire hose test with hose specifications of 25, 40, 50, 65, 80 and 100.
It is suitable for the impulse shock resistance test of fire emergency lights.
Fire Nozzles Jet Test Device is suitable for range test, flow test, spray angle and bloom angle measurement in the spray performance of fire water gun;
This Air Tightness Tester is suitable for the air tightness test of cart-type fire extinguishers and portable fire extinguishers within 50kg.
It is suitable for the static operating temperature test of sprinklers.Sprinklers whose operating temperature does not exceed 79°C shall use a water bath, and those whose nominal operating temperature shall exceed 79°C shall use an oil bath.
Comply with ISO 7165 and ISO 11601 standard,It is suitable for electrical insulation performance test of water-based fire extinguisher when spraying.
It is suitable for the electrical insulation performance test of powder extinguishing agent, and the electrical insulation is ≥5kv.
It is suitable for the air tightness test of the pressure indicator of the gas fire extinguishing system;
Fire resistance testing apparatus for grooved fittings in automatic sprinkler systems. It is widely used in the production inspection and development research of various fire hoses in production factories, product quality inspection institutes, scientific research institutions and other units, and other similar product related tests.
This Testing equipment Comply with DIN 14521-1987 standards ,it is suitable for the sealing performance, pressure resistance performance, outer diameter expansion rate and axial elongation rate test of fire hose reels of water, dry powder and foam fire extinguishing agents.
It is suitable for spray gun drop test. Hang the spray gun on the test stand, drop it from a height of 1.5m, and impact it on a 10cm-thick reinforced concrete board. After the test, the spray gun should be free of cracking and deformation and can be used normally.
It is suitable for evaluating the performance of rail train materials such as single or composite rigid materials, materials with adhesive coating, and flexible materials with a thickness greater than 5 mm.