Comply with ISO 7165 and ISO 11601 standard,It is suitable for electrical insulation performance test of water-based fire extinguisher when spraying.


Product Number:ZY6367-FE
Share:
  • Product Description

1. Scope of application

It is suitable for electrical insulation performance test of water-based fire extinguisher when spraying.

Hang a metal plate with a size of (1±0.025)m*(1±0.025)m vertically on the insulating bracket, connect the metal plate to the transformer, and establish a (36±3.6) AC voltage in kv. Fix the fire extinguisher on the insulating support, keep the nozzle at a distance of 1m from the center of the metal plate, energize the metal plate, turn on the fire extinguisher to spray, and measure the current flowing between the fire extinguisher and the ground not greater than 0.5mA.


2. Comply with the standard:

2.1 Comply with Section 7.13 "Electrical Insulation Test" of GB4351.1-2005 "Portable Fire Extinguishers" standard;

2.2 Comply with Section 6.7 "Electrical Insulation Test" of GA86-2009 "Simplified Fire Extinguishers", excluding "Droplet Test of Water Mist Fire Extinguisher".

2.3 Comply with GB8109-2005 "Wheeled Fire Extinguisher" Section 7.7 "Electrical Insulation Performance Test".

2.4 Comply with ISO 7165:1999 "Fire fighting—Portable fire extinguishers—Performance and construction".

2.5 Comply with ISO 11601:1999 "Wheeled fire extinguishers—Performance and construction".


3. Main technical parameters:

3.1 Test voltage: fixed voltage, (36±3.6) kv;

3.2 Current: 100mA, transformer with instrument output;

3.3 Leakage current: 0~10mA can be set;

3.4 Leakage current resolution: 0.01mA;

3.5 Metal size: (1±0.025)m*(1±0.025)m;

3.6 The metal plate and fixing frame are independent laboratories, and the space should not be less than 2.5m*2.5m; customers should prepare them by themselves;

3.7 Insulation bracket: can withstand more than 36kv;

3.8 When the leakage current exceeds 0.5mA, with sound and light alarm;

3.9 The injection device is pneumatically driven;

3.10 The jet gas is compressed air, and the air compressor needs to be provided by the customer;

3.11 Control part: for safety, it is designed for remote control;

3.12 Control box size: length 400mm*width 390mm*height 650mm

3.13 Fixture size: length 400mm*width 400mm height 1410mm

3.14 Size of metal plate mounting frame: length 1410mm*width 1020mm*height 1510mm

3.15 power supply; AC220V, 5KVA.