It is suitable for the maximum flattening force of 2 tons, the diameter is less than 10mm, and the rated voltage is 500V and 750V copper core copper or copper alloy sheathed mineral insulation flattening test.Comply with IEC 60702-1:2002 test standard.
1. Scope of application:
It is suitable for the maximum flattening force of 2 tons, the diameter is less than 10mm, and the rated voltage is 500V and 750V copper core copper or copper alloy sheathed mineral insulation flattening test.
2, meet the standards:
Comply with GB/T13033.1-2007, IEC 60702-1:2002 test standard.
3. Main parameters:
3.1 Maximum test force: 2000kg.
3.2 Displacement stroke: 30mm
3.3 Displacement resolution: 0.01mm.
3.4 Displacement speed adjustment range: 5-150mm/min.
3.5 Displacement rate control accuracy: when the rate is ≥5mm/min, within ±0.5% of the set value.
3.6 Anvil specifications: length 75mm, bottom width 25mm, fillet R10mm
3.7 Automatically calculate the displacement stroke and loading pressure according to the flattening coefficient.