HomeProducts Select by Industry Building Component Testing Equipment As4740 Ventilation And Rain Resistance Testing Machine for Building Louvers
As4740 Ventilation And Rain Resistance Testing Machine for Building Louvers
  • As4740 Ventilation And Rain Resistance Testing Machine for Building Louvers
As4740 Ventilation And Rain Resistance Testing Machine for Building Louvers

As4740 Ventilation And Rain Resistance Testing Machine for Building Louvers

Ventilation and Rain Resistance Testing Machine for Building Louvers is an apparatus water penetration resistance of louvers in compliance with AS4740 standards. This system simulates wind-driven rain conditions and measures louver effectiveness in restricting water ingress while maintaining optimal ventilation rates. 


Product Number:ZY6292B
Share:
  • Product Description

As4740 Ventilation And Rain Resistance Testing Machine for Building Louvers

What is the Ventilation And Rain Resistance Testing Machine for Building Louvers?


ZONSKY Ventilation and Rain Resistance Testing Machine for Building Louvers is an apparatus water penetration resistance of louvers in compliance with AS4740 standards. This system simulates wind-driven rain conditions and measures louver effectiveness in restricting water ingress while maintaining optimal ventilation rates. Equipped with precision airflow sensors, calibrated rain spray mechanisms, and high-resolution data logging, the machine provides accurate performance metrics, ensuring that louvers meet regulatory requirements for both ventilation efficiency and rain defense in varied environmental conditions.


Applicable to laboratory testing of ventilation and rainproof performance of building ventilation shutters. The test items include ventilation performance, static rainproof performance, and dynamic rainproof performance. The test object is limited to the building ventilation shutter specimen itself, and does not involve the connection between the building ventilation shutter and the enclosure structure


Compliance :AS4740 Natural Ventilators - Classification and Performance”


1731309410552008Main performance parameters:    


1. Equipment composition: It consists of a wind simulation system, an environmental chamber, a rainwater collection box, and an air flow measurement system. Overall composition of the testing equipment


2. Wind simulation system:


2.1 Air flow measurement box: The installation diameter is 2100mm long and 1100mm high;


2.2 Flow stabilization device: It is composed of three layers of flow stabilization nets, in which the ventilation areas of the flow stabilization nets are 60%, 50%, and 45% respectively, and the spacing between each layer of flow stabilization nets is 50 mm. The single-point flow velocity of plane Y is less than 1.25 times the average flow velocity of the plane.


2.3 Pressure difference measurement:


2.3.1 Use differential pressure gauge for measurement;


2.3.2 Measuring range: 0~500Pa, measuring accuracy is 1%;


2.4 Wind speed measurement:


2.4.1 Use anemometer for measurement;


2.4.2 Measuring error: 2% of the indicated value;


2.5 Air flow measurement:


2.5.1 Use mass flow meter for measurement;


2.5.2 Measuring range: (0.001~7) m3/s;


2.5.3 Measurement accuracy: ±2.5%;


2.6 Temperature measurement:


2.6.1 K-type thermocouple is used for measurement;


2.6.2 Measurement accuracy: 0.5℃;


2.7 Timer accuracy: 0.1s;


3. Environmental chamber: The size is 3000mm*3000mm*2000mm, and the opening side faces the wind simulation system and water spraying device;


4. Rainwater collection box: The size is 1250mm*l250mm*2000mm, and it is equipped with a water baffle;


5. Spray Spraying device:


5.1 Equipped with 4 matrix-distributed solid cone nozzles;


5.2 Nozzle spraying angle: 93°~115°;


5.3 Water spraying pressure: 0.03MPa;


5.4 Spraying volume: ≥3.7L/min;


5.5 Spraying system: automatically controlled by computer, 4 nozzles spray one by one, and the spraying interval time can be set (0~99s arbitrarily set);


6. Rain gauge:


6.1 Use a tipping bucket stainless steel rain gauge;


6.2 Rain gauge cylinder diameter: 200mm;


6.3 Resolution: 0.2mm;


6.4 Rain intensity range: 0mm~4mm/min;


6.5 Measurement accuracy: 2% of indication;


7. System control allowable error:


7.1 Water spray volume: ±2%;


7.2 Water collection volume: ±10%;


7.3 Ventilation volume: ±5%;


7.4 Wind speed: ±10%


8. Control system: It is composed of computer, PLC and module.


Email to this supplier
  • To:
    ZONSKY INSTRUMENT CO., LTD
  • *E-mail:
  • *Message:

    Your message must be between 20-8000 characters

HomeProducts Select by Industry Building Component Testing Equipment As4740 Ventilation And Rain Resistance Testing Machine for Building Louvers

Home

Product

Phone

About Us

Inquiry