It is suitable for fire-fighting soft reel and fire-fighting water gun spray test.This equipment only includes fire hose reel jet test, fire water gun jet test and flow test;
It is suitable for fire-fighting soft reel and fire nozzles spray test. Its design and manufacture refer to the standards of GB15090-2005 "Fire Hose Reel" and GB8181-2005 "Fire nozzles", using computer automatic control, automatic collection test Data, pressure control is precise, and formatted reports are automatically generated. The overall design is reasonable, the maintenance is convenient and fast; the automatic constant pressure, the slight leakage automatically replenishes the constant pressure; the high-pressure pipeline is made several times, and it is durable.
The working pressure is 0.20Mpa~4.0Mpa, and the flow rate is not more than 16L/S;
This instrument only includes fire hose reel jet test, fire water gun jet test and flow test;
Compliance:ISO 6182-6;EN 14540;NFPA 1961;BS 6391;AS 2792;
Applicable workpieces: fire nozzles DN65mm, DN50mm, DN40mm (medium pressure fire nozzles) and imported external thread M39*2 (high pressure water gun); hose reel: nominal diameter of 19mm;
2. Main configuration: The control cabinet is integrated by high-pressure pipeline, injection device and computer;
3. Test medium: water (15T reservoir, provided by the buyer);
4. Low pressure pump: 0~0.7Mpa, flow 100m³/H;
5. Pressure range: 0~4.0Mpa;
6. High pressure pump: 0.5~4.5Mpa, flow 12.5m³/H;
7. Pressure acquisition accuracy: ±0.05MPa;
8. Pressure sensing method: current transmitter method;
9. Frequency regulation range of frequency converter: 0~50Hz; 30/55KW frequency conversion speed regulation;
10. High pressure water supply system:
10.1 System composition: it consists of stop valve, filter valve, low-pressure water pump, multi-stage pressure pump, check valve, safety relief valve, hydraulic sensor, regulating valve and DN100/DN65/DN50/DN40 pipeline;
10.2 Low pressure centrifugal pump
10.2.1 Pressure: 0~0.7Mpa;
10.2.2 The flow rate is 93m³/H;
10.2.3 Power: 30kw;
10.2.4 Inverter: 30kw, controlled by computer.
10.3 D-type multistage high pressure pump:
10.3.1 Pressure: 0.5~4.5Mpa;
10.3.2 The flow rate is 12.5m³/H;
10.3.3 Power: 55kw;
10.3.4 Inverter: 55kw, controlled by computer;
10.4 Filter: DN100, filter mesh 10~30 mesh;
10.5 Globe valve: DN100;
10.6 Check valve: two to prevent pressure from backflow;
10.7 Safety release valve: DN80 is released when the pressure exceeds the test value, which plays a role in safety protection