It is suitable for the electrical insulation performance test of fire helmets.
It is suitable for the electrical insulation performance test of fire helmets.Place the helmet shell upside down on the wire mesh bracket in the test water tank, then pour water into the test tank and the shell until the water level rises to 20mm from the edge of the helmet. Insert the two electrodes connected to the output end of the high-voltage test bench into the water in the cap shell and the test tank respectively, wherein the electrodes of the test tank are connected with the wire mesh bracket as a whole. Then, start to boost the voltage to 2200v, keep it for 1min, and record the leakage current value.
Compliance:Section 6.10 "Electricity Insulation Performance Test" of GA44-2015 "Helmets for firemen".
1. Instrument composition: composed of electrodes, high voltage test bench, ammeter, timer, wire mesh bracket, test water tank, etc.;
2. High voltage test bench:
2.1 Output voltage: 0v~5000v;
3.2 Voltage error: ±1%;
3.3 Leakage current: (0~10) mA
3.4 Leakage current error: indication error ±1%;
3.5 Leakage current resolution: 0.01mA;
3.6 Timer: 0~99.99s, can be set;
3.7 Timing accuracy: s/h;
3.8 Electrode: the voltage output terminal is connected with a high voltage rod;
4. Normal temperature water tank (tank):
4.1 It is a single-layer stainless steel water tank;
4.2 Volume: (L50*W50*H40) cm;
4.3 It is normal temperature;
5. wire mesh bracket:
5.1 It is made of stainless steel wire mesh
5.2 The height is 50mm, and the length and width are 400mm