This Resistance To Corrosion Performance Test Apparatus Comply with IEC 60068-2-11:2021,ASTM G85-02,ISO 7165-2009 standards,Used in the internal and external corrosion test of 12kg fire extinguisher.
The Resistance to Corrosion Performance Test Apparatus is designed to evaluate the corrosion resistance of materials and components, particularly those used in harsh environments. This apparatus exposes specimens to corrosive agents or environmental conditions, such as salt spray or high humidity, to simulate long-term exposure. It measures corrosion rates, surface degradation, and material integrity, providing critical data to verify that materials meet durability standards for safety and longevity in corrosive settings.Used in the internal and external corrosion test of 12kg fire extinguisher.
IEC 60068-2-11:2021 "Environmental testing - Part 2-11: Test - Test Ka: Salt mist";
ASTM G85-02 "Standard practice for modified salt spray (fog) testing".
ISO 7165-2009 "Fire fighting—Portable fire extinguishers—Performance and Construction"
The whole set is made of PVC board, and the advanced three-dimensional reinforcement technology of ring belt is used inside, the structure is strong and never deformed. It is equipped with double over-temperature protection and low water level warning to ensure safe use. Imported temperature controller, digital display, PID control, high stability platinum temperature measuring probe, error ± 0.3 ℃. The test tank adopts steam direct heating method, the heating speed is fast, and the standby time is shortened. The spray tower is equipped with a conical diffuser, which has the functions of directing the mist, adjusting the amount of mist, and evenly falling mist. The pressure barrel adopts Henry's law to heat and humidify and provide the humidity required by the laboratory.
1. Studio size: height 1600mm* depth 1000mm* width 1000mm.
2. Laboratory temperature: 35°C/50°C.
3. Saturated air cylinder temperature: 47°C/63°C
4. Maximum capacity of test liquid: 30L.
5. Approximate external dimensions: width 1250mm* depth 1100mm* height 2000mm;
6. Applicable specification 12kg fire extinguisher.
7. Customers need to prepare their own list:
8. Type of water, air source or oil: tap water
9. Power distribution requirements: AC220V/50HZ power 2KW
10. Sample: fire extinguisher
11. Requirements for supporting facilities: one sewage outlet (connected to item 1 sewage outlet).