ZONSKY Magnetic Core Load Tester evaluates the mechanical integrity and load-bearing capacity of cables under conditions simulating core failure. It applies a specified load to cables with intentionally broken or compromised cores, measuring parameters such as tensile strength, load distribution, and residual structural integrity. This apparatus is suitable for load-breaking tests on various copper-clad soft wires. A flexible cord sample of appropriate length is fixed at one end to a rigid support, with a 0.5 kg hammer suspended 0.5 m below the support point to simulate real-world stress conditions.Talk To Our Team
Compliance
IEC 60227-1:2007, IEC 60227-2:2003 test standard
Load Broken Core Test Apparatus Main Parameters
Parameter
Specification
Test Station
1 station.
Load Drop Height
500 mm.
Load Drop Method
Free fall.
Load Lifting Method
The fixture on the lead screw drives the electromagnet to absorb and lift the load automatically.
Load Weight
500 g.
Load Quantity
1 piece.
Signal Current (On-Off State)
AC 0.1A.
Signal Voltage (On-Off State)
AC 12V.
Counter
1–9999 continuous display and adjustable setting; stops automatically when reaching the set value.