This Tracking Test Equipment Compliant with IEC60587:2007 standards,suitable for evaluating tests using electrical insulating materials under severe environmental conditions by measuring resistance to tracking and corrosion with liquid contaminants and sloped specimens.


Product Number:ZY6058B-ZN-A6KV
Share:
  • Product Description

Tracking Index Apparatus For High Voltage Leakage

What is the Tracking Index Apparatus For High Voltage Leakage?


The Tracking Index Apparatus for High Voltage Leakage is designed to evaluate the electrical tracking resistance of insulating materials under high voltage conditions. This apparatus applies a controlled voltage across a test specimen while simultaneously introducing a conductive liquid, simulating conditions that promote tracking and potential failure. It measures the time until tracking occurs and assesses the material's ability to withstand leakage currents, providing essential data for evaluating the safety and reliability of insulation in electrical applications.


compliance: IEC60587:2007 "Electrical insulating materials used under severe ambient conditions—Test methods for evaluating resistance to tracking and erosion".


Main parameters:


1 Test station: five stations


2 Transformer: output voltage AC0~6kv±5%, current 1600mA, power 10KVA


3. Test loop current: 60mA, when the high-voltage loop current reaches or exceeds 60mA±6mA for 2s~3s, the overcurrent delay relay acts to cut off the current, and the buzzer alarm indicates that the test product is unqualified. alarm sound;


4. Voltage regulator: 10KVA;


5. Filter paper size: It is made according to the standard size requirements, and the thickness of the filter paper is 0.15 ~ 0.17mm.


6. Dropping device: The height of the dripping device is adjustable, the flow rate of the contaminated liquid is adjustable at 0.075~0.9mL/min, and the test time can be preset.


7. Dropping interval time: 0~99.99S can be set.


8. Polluted liquid: ammonium chloride, isooctylphenoxypolyethoxyethanol, non-ionic wetting agent and distilled water or deionized water mixture. The resistivity of the contaminated solution at (23±0.05) Ω•m should be (23±0.05) ℃.


9. Electrodes: the thickness of the upper and lower electrodes is 0.5mm, made of 304 stainless material, and the size is in accordance with the standard size requirements


10. Power requirements: AC220 (±10%) V/50HZ.