ZONSKY Fire Extinguisher Drop Tester is designed to assess the durability and structural integrity of fire extinguishers under impact forces. This apparatus simulates drops, collisions, or accidental impacts by applying controlled force to the extinguisher, evaluating parameters such as casing resilience, seal integrity, and functional readiness after impact.Talk To Our Team
Test Method: Place the fire extinguisher upright so the axis of the steel hammer aligns with the axis of the fire extinguisher. Next, place the fire extinguisher horizontally with the headrest resting on the steel block. This ensures the center of the steel hammer hangs in the middle of the fire extinguisher head, and then the steel hammer falls freely to impact the fire extinguisher head part.
Compliance:
DIN 14521-1987
NF S61-820-11/N12010
NF S61-820-2/N12010
Fire Extinguisher Shock Test Apparatus Main Parameters:
Parameter
Specification
Height of the Bottom Surface of Steel Hammer
0.3–1.0m adjustable, tolerance: ±2mm
Steel Hammer Specifications
Diameter: 75mm, Weight: 4kg±0.1kg
Lifting Method of Hammer Body
The stepper motor drives the sprocket and chain to lift and lower the hammer body. The height can be adjusted as needed. Ascending speed: 500mm/min
Impact Height Positioning
The limit switch positioning protection is used, and any height positioning can be set