Electrical Insulation Test Apparatus

ZONSKY Electrical Insulation Test Apparatus is designed to assess the electrical insulation properties of fire extinguisher components. It ensures safety during handling and operation near electrical sources. The equipment applies high voltage to test insulation resistance, dielectric strength, and leakage current, confirming that the materials and structure of the fire extinguisher prevent electrical conductivity.Talk To Our Team

This equipment is suitable for testing the insulation performance of water-based fire extinguishers while spraying. To perform the test, the operator should hang a metal plate with a diameter of φ120 (±0.025) mm and thickness t(±0.025) mm vertically on an insulating bracket. They then connect the metal plate to a transformer and apply an AC voltage of (3.6±0.5) kV. The operator must fix the fire extinguisher on the insulating support, maintain a 1-meter distance from the metal plate’s center to the nozzle, turn on the transformer, start spraying, and measure the current between the extinguisher and the ground. This current must not exceed 0.5 mA.

Compliance:

    • Section 6.7 “Electrical Insulation Test” of GA86-2009 “Simplified Fire Extinguishers”, excluding “Droplet Test of Water Mist Fire Extinguisher”.
    • ISO 7165:1999 “Fire fighting—Portable fire extinguishers—Performance and construction”.
    • ISO 11601:1999 “Wheeled fire extinguishers—Performance and construction”.

Electrical Insulation Test Machin Main technical parameters:

ParameterSpecification
Test voltageFixed voltage, (3.6±0.5) kV
Current100 mA, measured with the instrument output
Leakage current range0–10 mA, adjustable
Leakage current resolution0.01 mA
Metal plate sizeφ120 (±0.025) mm × t(±0.025) mm
Minimum laboratory space2.5 m × 2.6 m; metal plate and frame supplied by user
Insulation bracket capacityWithstands more than 36 kV
Leakage current alarmSound and light alarm triggers when leakage exceeds 0.5 mA
Injection devicePneumatically driven
Jet gasCompressed air (air compressor to be provided by customer)
Control systemRemote control with built-in safety features
Control box dimensions410 mm (W) × 390 mm (D) × 650 mm (H)
Fixture dimensions410 mm (W) × 400 mm (D) × 1410 mm (H)
Metal plate mounting frame1410 mm (L) × 1020 mm (W) × 1510 mm (H)
Power supplyAC220V, 5 kVA

 

Electrical Insulation Test Apparatus tests insulation performance to ensure fire extinguishers meet electrical safety standards.