Fire Hose Reel Testing Device

ZONSKY Fire Hose Reel Testing Device is designed to assess the airtightness and pressure retention capabilities of fire hose reels. This apparatus subjects the hose reel and its connections to high-pressure water tests to detect leaks and verify sealing integrity.Talk To Our Team

It is suitable for testing the sealing performance, pressure resistance, outer diameter expansion rate, and axial elongation rate of fire hose reels with water, dry powder, and foam fire extinguishing agents. It is applicable to the maximum working pressure of 0.4 MPa, with a maximum diameter of the hose being 38mm.

Compliance:

DIN 14521-1987, NF S61-820-1/IN12010, NF S61-820-2/IN12010

Main Technical Parameters:

ParameterValue
Instrument CompositionHydraulic test bench, air pressure test bench, test part, hose performance test device, and control part
Hydraulic Test Bench
Test MediumPure water
Pressure Range0 – 15 MPa
Boost Rate5 – 10 MPa/min adjustable
High Pressure Water Output20 L/min
Pressure Accuracy±0.005 MPa
Pressure Sensing MethodCurrent transmitter method
Voltage of Voltage Stabilizer25 MPa
Pressure Collection Interval0.1 s
Pressure Range of High Pressure Pump0 – 1.7 MPa
Frequency Modulation Range of Inverter0 – 50 Hz
Pressure Holding Time0 – 99.99 min
Pressure Display FluctuationWhen the pressure is less than 3.0 MPa, fluctuation is ≤ ±0.03 MPa. When it is greater than 3.0 MPa, fluctuation is ≤ ±0.03 MPa.
Diameter of Pressure PipeDN25 seamless steel pipe and rubber hose

Fire Hose Reel Testing Device Additional Technical Parameters for Air Pressure Test Bench:

ParameterValue
Air Pressure Test Bench
Pressure Range0 – 10 MPa
Test MediumAir
Medium TemperatureNormal temperature
Pressure Measurement Accuracy±0.5% Full Scale (FS)
Pressure Control Accuracy±1.5%
Measuring Range0 – 99%
Air SourceCompressed air: 0.1 MPa (a) ~ 0.8 MPa (b); compressor used to provide air source
Control ModeAutomatic/manual
Boost Rate0.1 MPa/min ~ 0.6 MPa/min (adjustable)
Test Part
Number of Test Pieces1 piece, the whole disk placement test
Test SpaceSuitable for a test space with a test length of 1.2m
Observation WindowWith explosion-proof observation window
Hose Performance Test
ComplianceComplies with GB15009-2005 Section 6.8 Hose Performance Test, but does not include low-temperature test (must be purchased separately)
External Diameter Expansion & Axial Elongation Test Device
Test StandOne test stand
Smooth ShaftsTwo shafts, one with a diameter of 150 mm, the other of 200 mm
Suspended Mass4.5 kg weight
Control Section
Computer & PLCUsed to collect and control data
Voltage StabilizationControlled by frequency converter
Pressure Holding Time0 – 99.99 min
Dimensions
Host VolumeLength: 2m; Width: 0.85m; Height: 1.65m
Control CabinetLength: 1.38m; Width: 1.15m; Height: 1.6m
Weight of Whole Machine550 kg

 

Fire Hose Reel Testing Device evaluates the performance, durability, and pressure resistance of fire hose reels Compliance: 1SO 6182-6/EN 14540/NFPA 1961Fire Hose Reel Testing Device